TIMER PROGRAMMING.
IMPORTANT. The timer as supplied factory is not recorded in any kind of timer, or time to work, you must schedule it
before first use.
Failure to act as a type 1 program, time 1 second.
STEPS TO SET THE TIMER
Disconnect the power
Select TIMER dips in the desired pattern
Select from the TIMER SCALE Dips desired time interval
Select the desired time adjustable potentiometer Once these 3 steps connect the power and the timer is programmed and
and ready to work.
Note. If you chose a starting model for voltage at power ripped
OPERATION
The timer is programmed and ready to go turn the power.
To start the timer press START button.
To stop / reset at any time tempización press STOP button
IMPORTANT. During the working time both DIPS programming time as the potentiometer are ignored by the timer, so you
can no longer function reschedule any work until the time runs out
RESCHEDULE. Disconnect the power and perform the same steps as indicated in the previous section PROGRAM TIMER
OUTPUT CONNECTION. LOAD. The output is controlled by a relay device that supports any type of load does not
exceed 3 A. The relay has three output terminals. The rest normally open (NO), the normally closed at rest (NC), and the
common operation of this mechanism is identical to a switch, whose two terminals NA and the common To perform the
inverse function must be used NC and Common terminals The figure shows the typical connection for a device with operation
to 12 V. DC. and another operating at 230 V. AC
12V DC
AC
AC
ABOUT THE OUTPUT. During operation of the circuit, and according to its load, may cause a fluctuation or an incorrect
operation of the output. If this occurs, install a spark between the two circuit relay contacts used in the connection, as shown
in the drawing
AC
NOTE: To connect loads to 12 V. DC resistance and to eliminate single capacitor
4