SDS
_____________________________________________________________________________________________
respirable dust natural
(vacated) TWA: 10 mg/m
3
total
dust synthetic
(vacated) TWA: 5 mg/m
3
respirable fraction synthetic
TWA: 15 mppcf natural
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 1
mg/m
3
Cu dust and mist
TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu
dust, fume, mist
IDLH: 100 mg/m
3
dust, fume and
mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume
Aluminum
7429-90-5
TWA: 1 mg/m
3
respirable fraction TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 15 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction (vacated)
TWA: 5 mg/m
3
Al Aluminum
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
Carbon black
1333-86-4
TWA: 3 mg/m
3
inhalable fraction TWA: 3.5 mg/m
3
(vacated) TWA: 3.5 mg/m
3
IDLH: 1750 mg/m
3
TWA: 3.5 mg/m
3
TWA: 0.1 mg/m
3
Carbon black in
presence of Polycyclic aromatic
hydrocarbons PAH
Phosphate(1-), hexafluoro-, lithium
21324-40-3
TWA: 2.5 mg/m
3
F TWA: 2.5 mg/m
3
F
TWA: 2.5 mg/m
3
dust
(vacated) TWA: 2.5 mg/m
3
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL: Occupational Safety and Health
Administration - Permissible Exposure Limits Immediately Dangerous to Life or Health
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992)
Appropriate engineering controls
Engineering Measures
Showers
Eyewash stations
Ventilation systems
Individual protection measures, such as personal protective equipment
Eye/face protection
Face protection shield.
Skin and body protection
Wear protective gloves and protective clothing. Long sleeved clothing. Chemical resistant
apron. Impervious gloves.
Respiratory protection
If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved
respiratory protection should be worn. Positive-pressure supplied air respirators may be
required for high airborne contaminant concentrations. Respiratory protection must be
provided in accordance with current local regulations.
Hygiene Measures
Avoid contact with skin, eyes or clothing. Wear suitable gloves and eye/face protection. Do
not eat, drink or smoke when using this product. Take off contaminated clothing and wash
before reuse. Contaminated work clothing should not be allowed out of the workplace.
Regular cleaning of equipment, work area and clothing is recommended. Wash hands
before breaks and immediately after handling the product. For environmental protection,
remove and wash all contaminated protective equipment before re-use.
9. PHYSICAL AND CHEMICAL PROPERTIES
Physical and Chemical Properties
Physical state
Solid
_____________________________________________________________________________________________
Revision Date 05-Jun-2015
Page 6 / 13