Instructions / Assembly

Instruction / Installation Sheet
66 Clip Connection Block
No. 5540
DISTRIBUTED BY: HOME DEPOT U.S.A., INC.
2455 PACES FERRY RD., N.W.
ATLANTA, GA 30339
FOR ASSISTANCE, CALL:
1-800-394-7519
HOMEDEPOT.COM
MADE IN CHINA
Parts Included:
● 50 Pair 66 Block
● 89D Mounting Bracket
● 50 Binding Clips
Tools Needed:
● Impact Punch-Down Tool with 66 Blade
● Screw Driver
● Wire Cutter and/or Wire Stripper
The CE Tech 50 Pair 66 Block can be mounted vertically or horizontally on various surfaces.
Typical installations are mounted vertically on a plywood panel.
Installation Instructions:
Step 1: After determining your desired location, detach the 89D Mounting Bracket from the 50 Pair 66 Block by gently pulling each of the four (4) clips
that hold them together. Mount the 89D Mounting Bracket to the plywood panel with two (2) wood screws (screws not included).
Step 2: Route your cables through the top and/or bottom of the 89D Mounting Bracket, then back out either the left and/or right side. Place the 50 Pair
66 Block on the 89D Mounting Bracket and “click” into place.
Step 3: To terminate conductors, remove the minimum amount of the cabling jacket from the UTP cables (or similar).
NOTE: When Cat 5e performance is needed, it is necessary to insure proper pair twisting of the UTP cable. Do so by removing minimum
amount of cabling jacket. The pair twist must come within ½ inch of the points of termination.
Step 4: Leaving each twisted pair together, route wire pair through the desired slot. Place each wire in its own clip adjacent to the slot the wire pair is
routed through. Terminate each wire to the corresponding clip using an Impact Punch-Down Tool with 66 Blade.
NOTE: To prevent damage to the clips on the block, keep the Impact Punch-down Tool perpendicular to the block while punching down wires.
Step 5: Route cross-connect wire pairs through the same slot that the desired horizontal or backbone cable pair is located. Bridging clips are included
for use where applicable.
NOTE: Use wire cutters to remove any excess wire after punch down at the point of termination.
5540 Rev. 1
CE Tech’s products shall be installed and used only as indicated in CE Tech’s product instruction sheets.
Caution:
• Never install low voltage wiring during lighting storms.
• Never touch un-insulated wires or terminals unless the wire has been disconnected at its network interface.
• Use caution when installing or modifying data or telecommunication lines.
• DO NOT alter, change, or disconnect existing telecommunication wires if you are unsure of their purpose or function.
• It is NOT recommended to install this product in close proximity to an electrical service panel to prevent interference from electrical current.
Important Instructions:
• Read and understand all instructions.
• Do not use this product near water, for example near bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.
• SAVE THESE INSTRUCTIONS.
Step 1 Step 2 Step 3 Step 4 Step 5