Technical Specs
5
www.usautomatic.com
5 Programming
Terms to Understand
Access Code – Is the 5 digit code entered on the keypad to operate the gate.
Option available is to create a code containing less than 5 numbers and use the # sign as the
last key in the code. Example code "5#" or "1234#" the # is part of the access code.
ACCESS CODE CAN NOT BE THE SAME AS THE MASTER PASSWORD.
Master Password – The 5-digit code used to access programming features. Factory default
is “11111”. This should be changed for security reasons.
NOT USED TO OPEN GATE- CANNOT BE THE SAME AS THE PUK or ACCESS CODE.
Channel 1 – P1 (relay 1) is pre-wired to the Push Button input.
Channel 2 – P2 (relay 2) is pre-wired to the “Open/Free Exit” input.
Keypad Security Code (Dip Switch Code) – This code makes your keypad unique to your
installation. Keypad does not have dip switches like the transmitter; instead it has virtual dip
switches which may be programmed.
PUK Code – “Password Unblocking Key.” The PUK code is located inside the keypad and is
needed when the master password has been lost. Record PUK code: ____________
Quick beeps – the keypad is sending a signal to the receiver. Valid access code was entered.
NOTE: Do not install keypad until
“Create Communication with Receiver" has been completed.
Create Access Code: code you use to operate the gate
•
Enter the current Master Password
•
Enter “9”. If correct, 2 short beeps (if 1 long beep is heard, start over with first step)
•
Enter the new Access Code (up to 5 digits), if less than 5 digits, “#” is required.
•
Enter “9”.
•
Enter the new Access Code again to verify.
•
Enter “1”, “2”, “3”, “4” identifying which keypad channel the Access Code is
Create Communication with Receiver
•
Enter the Access Code created above
•
Holding the last key of the code - keypad beeps while last key is depressed.
•
Press the P1 button on the receiver and hold until LD light comes ON.
Programming is complete
•
*
For Open Only or Hold Open function program to P2 channel.
*
For Hold Open function receiver P2 channel must be set to Latch Mode.
Latch mode - press the P2 button on receiver and hold once the LD light comes ON
immediately release and press the P1 button one time.
Example:
Access code created using a 1 in the last step could be programmed to P1 channel. Access
code created with a 2 in the last step could be programmed to P2 channel. If this was done
then both access codes would have to create communication with receiver in the steps below.
learned to. If correct, 2 short beeps (If 1 long beep, start over with first step).
Enter # to exit (long Beep) or wait for time-out (long Beep) or start again from