User's Manual

DigitagLR to DG-502UM
STAND-ALONE LONG RANGE ACCESS CONTROL
Screen
1 2 3
4 5 6
7 8 9
Þ
0
#
C R T R C T S S B M E 1 2 3 4 5 6 12 V 12
12 3
ST1
RL1 RL2
12V +
12V -
230V~
V1
MAGNET
V2
Strike
PB1
PB2
+
IN-
D0
L
6
3
D1
IN+
V
This device comes with a varistor. The varistor must be connected to the
strike terminals operated by the device.
If this product works with more strikes, each of them should have a
varistor.
* When connecting a DIGITAG-LR long range receiver to the DG-502UM
blease used Belden 9534 screened cable or equivalent. The screen is
connected at the DG-502UM in the spare V terminal but insulated inside
the DIGITAG LR case and never terminated
Relay 1 ( RL1 ) is active relay when connecting the Digitag LR receiver as
shown
WIRING DIAGRAM DG-502UM-DIGITAG-LR
B Push button 1
E Push button 2
M Common PB1 PB2
R N/C contact
C Common
T N/O contact
V1 Varistor RL1
V2 Varistor RL2
ST1 Reset jumper
S,S Trigger output
RL1 Door 1 relay output
RL2 Door 2 relay output
DG502 DIGITAG LR
12 IN+
V SCREEN *
4 IN-
66
33
Digitag-LR - Use and installation manual
Pag. 5