Edition 06/2004 G0301FR0222V01 PROMI 1000 WIRING DIAGRAM AND INSTRUCTION STAND ALONE ACCESS CONTROL SYSTEM This device comes with a varistor. The varistor must be connected on the strike terminal (electromagnet…) operated by the device. If this product operates more than one strikes, each of them should have a varistor. The varistor controls the overload produced by the strike coil – back emf.
Edition 10/2003 PROMI 1000 USER MANUAL I. PRESENTATION DU PRODUIT.............................................................................................................................. 3 A. Product presentation ........................................................................................................................... 3 B. Factory Default Values ........................................................................................................................ 4 C.
Edition 10/2003 I. PRESENTATION DU PRODUIT A.
Edition 10/2003 B. Factory Default Values Operating mode: 0 badge and Pin code Door open time: 1 second Alarm time delay: 00 alarm disabled Key-in keypad time: 10 seconds Master code: 12345 No time zone No Holiday Anti pass back disabled DTR signal on for printer Programming time : 2 minuts C.
Edition 10/2003 reference: TP50XSE2C RS232 with DTR signal (printer on line) 9600 bauds 1 start Dip switchs set up on the printer ON 7 bits Parity: even 1 2 3 4 5 6 7 8 1 stop IBM mode 40 characters CR = skip line DTR signal: high: printer on line low: printer off line Brown Terminal White TX DT M RX 3 Green 2 1 4 5 Yellow Back side Paper error: When paper roll is finished, the printer LED flashes fast, The data is stored in the memory buffer of the printer until it is full.
Edition 10/2003 II. PROGRAMMING A. Colors and audible signals O2 The letter in bolt represents the LED color. (O for orange, G for green and R for red) the digit represents the number of beep emitted. G1 The LED turns green and the 1 beep is emitted. R1 The LED turns Red and 1 beep is emitted. B. Main menu Important: Refer to the one page programming Enter the master code twice O2 Enter the master code twice (12345 default). The LED turns on to orange and 2 audible beeps are emitted.
Edition 10/2003 --- Present the badge in front of the PROMI1000 or in front the external reader (nal reader: see Menu 10) O1 OR Select a user number, enter the 3-digit user number from 000 to 999 --- If the user number is available the LED lights on in Green G1 present the badge in front the PROMI 1000 or in front of the external reader O1 --- If the user number is not available R1 enter another user number or press on * twice G1 to delete the badge and Pin code.
Edition 10/2003 OR Press 2 to select badge OR Pin code operating mode. The LED lights on in green G1 Then press #. Press # go The PROMI 1000 returns to the main menu O1 back to MENU E. Menu 02 – Door release time Enter 02 to enter in the door release time menu Enter the time in seconds from 01 to 99 for a momentarily output or 00 for a latched output. The LED lights on in green G1 Press # go Then press #. back to MENU The PROMI 1000 returns to the main menu O1 F.
Edition 10/2003 H. Menu 05 – Setting date and hour Enter 05 to enter in the date and hour menu Enter the hour and minutes then the day, month, year and the week day Week day: G1 Monday --------- enter 1 Tuesday -------- enter 2 Wednesday --- enter 3 Thursday ------ enter 4 Friday ---------- enter 5 Saturday ------- enter 6 Sunday --------- enter 7 Example: 09h26, 02 September 2003, Tuesday. Enter 09 26 02 Then press #. 09 03 2 Press # go O1 back to MENU The PROMI 1000 returns to the main menu I.
Edition 10/2003 J. Menu 07 – Holidays Press 07 to enter in the holidays menu 16 different holidays can be programmed, enter the a holiday number from 01 to 16 R1 Then enter the day and month for this holiday Example: 25 October, enter 25 10 The LED lights on in green Then press #. V1 Press # to go back to the Main MENU The PROMI 1000 returns to the main menu O1 OR Enter another holiday. K.
Edition 10/2003 To stop the printer at any time keep pressing on the 0 key until the LED lights on in green and a beep is emitted. At the end of the printing the a message “END PRINTING” appears on the report. The LED lights on in green G1 Then press #. Press # to go back The PROMI 1000 returns to the main menu O1 to the Main MENU OR Press 2 to print the configuration report of the PROMI 1000 control unit.
Edition 10/2003 Press 3 to print all the code of badge and Pin code. To abord the printing report, keep pressing on the 0 key until the LED lights on in green and a beep is emitted.
Edition 10/2003 The LED lights on in green G1 Then press #. Press # to go back The PROMI 1000 returns to the main menu to the Main MENU O1 To program badges and Pin code selec t Menu 00. The built-in reader of the controller is set back as the default badge enrolment unit once you exit from programming. N.
Edition 10/2003 Press 1 to authorize the access for the selected user number (cardholder) or press 0 to deny access for the selected user number during the holidays. The LED lights on in green G1 Then press #. Press # to go back to the Main MENU The PROMI 1000 returns to the main menu O1 OR Press * to authorize the access to all the cardholder O1 Press # to confirm and wait 5s until the new configuration is set for all the cardholder.
Edition 10/2003 The LED flashes in red and a beep is emitted. Remove the jumper from 2-3 position then the unit goes back to stand-by mode. OR Keep the jumper on 2-3 position to reset the badges, pin codes, schedules and holidays from the PROMI 1000 memory. The LED flashes in red during 5 seconds then the LED lights on in red during the reset. The LED starts flashing in orange when the reset is completed and a beep is emitted. Remove the jumper from 2-3 position to go back to stand-by mode.
Edition 10/2003 After 3 incorrect badge and/or PIN code are entered, the PROMI 1000 reader and the second proximity reader are locked out during 2 minutes and the alarm relay is activated. 2 audible beeps sound when the badge/PIN code are not valid. The LED lights on in red during the time of the lockout. The LED flashes in orange when the lockout is finished. D.
Edition 10/2003 Note: 1. During an alarm the reader and the request-to-exit are enabled. 2. To cancel the alarm go to Menu 03 in programming and enter 00. Events Quand l’alarme est commandée (forced door open, door ajar or lockout alarm) the following messsages are printed on the event report «Alarm» and «Alarm end» with the day and hour of the event. Event Alarm Alarm cleared Date 25.09.03 25.09.03 Heure Mode 17.38 17.44 2 2 F. Memory The memory unit on the PROMI 1000 can be removed.
PROMI 1000 IV. PROGRAMMING DIAGRAM Key-in programming time: 2minutes and key-in keypad time: 10 seconds, no schedule no holiday Present a badge in front of the reader Free user number G1 Present badge O1 R1 M E N U 01 R1 02 Press ** G1 Then enter a user number O1 Or present a badge Operating mode Press 0 for badge and Pin code Press 1 for badge only Press 2 for badge or Pin code Door release time: Enter 01 to 99 sec.
R1 G1 # exit from MENU O1 G1 # exit from MENU O1 G1 # exit from MENU O1 G1 # exit from MENU O1 # exit from MENU O1 Badge enrolment reader: press 1 to select the remote proximity reader press 0 to select the PROMI 1000 reader 10 R1 11 Press 0 Press 1 R1 Press 2 Delete Schedules: to delete the schedule of mode 0 then press * twice to delete the schedule of mode 1 then press * twice to delete the schedule of mode 2 then press * twice R1 Delete the holiday periods 12 Enter 01 to 16 R1 R1
V. WIRING DIAGRAM Reset of master code, badges, pin codes and évènts ST1 ST1 without PROMI 1000 normal mode Remote reader 60cm minimum 12 V 1 4 5 3 2 ST1 RL2 RL1 2 TX DT M RX 2 1 E M B 3 5 A R C T 12 V 230 V Door contact White Green Brown Yellow 2 2 PB Input voltage 12VAC/DC Input voltage 12VAC/DC 230 V Input voltage 12VAC/DC 230 V V Strike 5 The PROMI 1000 and the remote reader must be separated between each other by 60 cm.
Terminal Signification 12 V T C R A 5 3 B M Input voltage 12VAC or DC Input voltage 12VAC or DC N/O contact Common contact N/C contact N/O alarm contact Remote reader red LED Remote reader green LED Request-to-exit input Common of Push button and door contact Alarm input Remote reader data Remote reader buzzer RX printer Common printer DTR signal printer on line TX printer V : Varistor E 1 2 RX M DT TX 21
User number 22 Badge Pin Code Username Holiday
VI. TEMPLATE PROMI1000 23 135 Wiring access Area 30 x 40 24 120 105 20.5 15 38 61 75.