Specifications
JCM Part No. 960-000058R_Rev. 2 © 2008, JCM-American Corporation
23
EBA-03 Bill Validator Section A
T
EST
N
O
. 4 A
CCEPTOR
I/F T
EST
This test checks the Acceptor’s Input/Output signal
line status. Use the ACK, REJ, and ENABLE but-
tons on the VM-450 to make sure the signal line is
wo
rk
ing as follows:
1. Set the initial DIP Swit
ches according the
Figure A-10 illustration.
2. Turn off power to the VM-450.
3. Set DS-1, Switches #1, #2, and #3 to ON.
4. Turn power to the VM-450 ON, and change
DS-1, Switch #
1 to OFF to begin running the
tests listed in the Figure A-11 procedure.
T
EST
N
O
. 5 A
CCEPTOR
F
UNCTION
T
EST
This test performs a continuous unit cycling until
an error occurs.
1. Set the initial DIP Switches according to the
Figure A-12 illustration.
2. Turn off power to the VM-450.
3. Set DS-1, Switches #1, #2, #3, and #4 ON.
4. Turn on power to the VM-450 and change
DS-1,
Switch #1 to OFF to begin running the
tests.
If an error occurs during the test operation, the
ABN LE
D o
n the VM-450 will light and the test
operation will stop.
The Red LED on the CPU board will begin blink-
ing in flashing sets. The cause of the problem can
b
e
determined by counting the number of flashes
between each pause. (See “Error Codes” on
page A-24).
T
EST
N
O
. 6 B
ILL
A
CCEPTOR
T
EST
This test performs a bill acceptance test of the sys-
tems sensors.
1. Set the initial DIP Switches according to the
Figure A-13 illustration.
2. Turn off power to the VM-450.
3. Set DS-1, Switch #1, #2, and #5 ON.
4. Turn on power to the VM-450 and change
DS-1
,
Switch #1 to OFF to begin running the
tests.
When a Bill is accepted the VM-45
0 and Vend 1
LED will blink rapidly three (3) times.
If a Bill is not accepted or rejected, refer to the
Red a
n
d Green LEDs located on the EBA-03 for
the Error Code generated as listed in Table A-2 and
Table A-3 on this page.
Figure A-9 Sensor “F” Detection Lit LED
Figure A-10 Acceptor I/F Test DIP Switch
Settings
The VEND 1 LED
Lights when the ACK
(OK) Button is Pushed.
Move the Enable/
Disable Toggle Switch
to “ENABLE” and the
BSY LED will Light
Push the REJ Button
when the ABN LED
Lights
Figure A-11 EBA Test #4 Lit LED Indications
Figure A-12 Acceptor Function Test DIP
Switch Settings
Figure A-13 Bill Acceptance Test DIP Switch
Settings
NOTE: When performing this test, the
Acceptor will not return to the test standby
mode if you turn DS-1, Switch#1 to ON
again. It is necessary to power off the
unit, place DS-1, Switch #1 in the ON
position, and then reapply power.










