Specifications
JCM Part No. 960-000058R_Rev. 2 © 2008, JCM-American Corporation
14
Section 4 EBA-03 Bill Validator Calibration
3. Click the Screen Button to con-
tinue the installation.
4. To complete the software installation on
yo
ur hard drive, click the lar
ge icon shown in
Figure 4-6 and follow the screen prompts.
Using the Calibration Software
With the cabling attached as shown in the Figure 4-
1 illustration, begin the tests by:
1. Double-click on the EBA-03 icon. The open-
ing screen shown in Figure 4-7 will appear.
Click and follow the on-
screen instructions.
2. Once the motor speed test is finished, open
the top of the Acceptor and insert the White
Refer
ence Paper (Part No. 074541) into the
insertion slot.
3. Then click on the Screen
Button. When that test is finished, replace
th
e White Reference Paper with
the Black
Reference Paper (Part No. 074542).
If there is a calibration problem, an ERROR
m
essage will appear in Figure 4-8 indi
cating
where the possible problem location could
be.
Sensor Names and Locations
If an error does occur during the previous tests, use
the error information listed in Table 4-1 and the
location information shown in Figure 4-9 to deter-
mine which sensor may be at fault and where that
particular sens
or is located.
Figure 4-5 Second Software Install Screen
Figure 4-6 Third Software Install Screen
Figure 4-7 Initial Adjustment Software Screen
Table 4-1 Error Codes
Error Name Sensor Name
l3t_ir L3DI/L3PT
l3t_gn L3UG/PTL3
l3d_ir L3DI
l3d_rd L3DR
l3u_ir L3UI
l3u_gn L3UG
c0t_ir C0DI/C0PT
c0t_rd C0UR/PTC0
C0D_IR C0DI
c0d_rd C0DR
c0u_ir C0UI
c0u_rd C0UR
r3t_ir R3DI/R3PT
r3t_rd R3UR/PTR3
r3d_ir R3DI
r3d_gn R3DG
Figure 4-8 Final Adjustment Software Screen
NOTE: This test only takes a second.
Remove the Black Reference Paper
and click “Next” again.