Specifications
JCM Part No. 960-000058R_Rev. 2 © 2008, JCM-American Corporation
10
Section 2 EBA-03 Bill Validator Installation / Operation
Figure 2-3 illustrates the internal DS-2 DIP Switch
settings when the Serial Interface (I/F), o
r the Pulse
Interface is configured.
Preventive Maintenance
It is important to keep the bill path, rollers, and
belts clean. The sensor lenses are transparent
surfaces, and are made of a polymer material.
Handle them with extreme care.
To clean the lenses, use a lint-free cloth and mild
non-a
brasive detergent such as liquid dish soap
mixed with water (See Figure 2-4).
8
X
7
Accept
X Reject
*.NOTE: Numbers 1-7 indicate different denominations in any currency.
Table 2-5 DIP Switch 1 (DS-1) Settings
DIP Switch
No.
Position
Denomination
(see NOTE below)
*
Accept/
Reject
ON OFF
NOTE: Turn DS-1, Switch #1
ON to enter the test mode.
When serial I/F is used, set DS-2,
Switch #1 to ON.
When pulse I/F is used, set DS-2, Switch
#1 to OFF
DS-2 Switches #2 and #3 determine the
pulse width
DS-2 Switch #4 selects the pulse option
DS-2 Switch #5 controls the exit sensor:
ON = Disabled,
OFF = Enabled (Normal operation)
DS-2 Switch #6 controls the INHIBIT
signal:
OFF = high active,
ON = low active
DS-2 Switch #7 controls the ABN signal:
OFF = high active,
ON = low active
DS-2 Switch #8 controls the ACC-
EPTANCE rate:
ON = high acceptance,
OFF = low acceptance
Figure 2-3 DIP Switch 2 (DS-2) Settings
NOTE: These settings vary according to the
software version
WARNING: Do not use alcohol or paint
thinner for cleaning surfaces!
Figure 2-4 EBA Bill Path Cleaning