I Office: (800) 683-7248 Technical Support: (702) 651-3444 E-Mail: techsupport@jcm-american.com Web-Site: FAX: (702) 651-0214 www.jcm-american.com Bill Acceptor Series EBA-03 Bill Validator Operation and Maintenance Manual (Revision 2) JCM Part No. 960-000058R_Rev.
JCM is a registered trademark of JCM American Corporation. All other product names mentioned herein may be registered trademarks or trademarks of their respective companies. Furthermore, ™, ® and © are not always mentioned in each case throughout this publication.
EBA-03 Bill Validator Table of Contents TOC Page 1 GENERAL INFORMATION......................................................................................1 Introduction..................................................................................................................... 1 Specifications ................................................................................................................. 2 Primary Component Parts .................................................................
EBA-03 Bill Validator Table of Contents THIS PAGE INTENTIONALLY LEFT BLANK JCM Part No. 960-000058R_Rev.
EBA-03 Bill Validator List of Figures LOF Page Figure 1-1 EBA-03 Bill Validator ...................................................................................1 Figure 1-2 EBA-03 Primary Component Parts..............................................................2 Figure 1-3 Precautionary Symbols ...............................................................................3 Figure 1-4 EBA-03 Bill Validator Dimensions ...............................................................
EBA-03 Bill Validator List of Figures Continued Page Figure A-10 Acceptor I/F Test DIP Switch Settings .....................................................23 Figure A-11 EBA Test #4 Lit LED Indications ..............................................................23 Figure A-12 Acceptor Function Test DIP Switch Settings ............................................23 Figure A-13 Bill Acceptance Test DIP Switch Settings ................................................23 JCM Part No. 960-000058R_Rev.
EBA-03 Bill Validator List of Tables Page LOT Table 1-1 Table 1-1 Table 2-1 Table 2-2 Table 2-3 Table 2-4 Table 2-5 Table 4-1 Table 5-1 Table A-1 Table A-2 Table A-3 General Specifications ..................................................................................2 Country Code Listings...................................................................................4 Serial I/F (ID-044C) Pins Assignments .........................................................
EBA-03 Bill Validator List of Tables THIS PAGE INTENTIONALLY LEFT BLANK JCM Part No. 960-000058R_Rev.
EBA-03 Bill Validator Bill Acceptor Series Section 1 1 GENERAL INFORMATION This manual provides a general overview of the advantages and options of the European Bill Acceptor Validation Unit (EBA-03) pictured in Figure 1-1.
Section 1 EBA-03 Bill Validator General Information Specifications Table 1-1 lists the EBA-03 General Specifications. Table 1-1 General Specifications Condition Function Acceptable denominations: DIP Switch selectable Insertion direction: Four-way Acceptance rate: 90+% in normal acceptance mode.
General Information EBA-03 Bill Validator Precautions Type 1 Section 1 2. (Type 2) Do not expose the unit to water. The unit contains several precision electronic devices which can be damaged if water or any liquid is sprayed or spilled into the unit. Type 2 3. (Type 3) Do not install the unit into a dusty environment. Dust may affect the sensor’s performance.
Section 1 EBA-03 Bill Validator Country Codes Table 1-1: Country Code Listings (Continued) Table 1-1: Country Code Listings Country General Information Country Country Code Country Code Iceland ISL Antilles ANT India IND Argentine ARG Israel ISR Australia AUS Italy ITA Austria AUT Italy ITA8 Austria AUT4 Italy ITA9 Barbados BRB Japan JPN Belgium BEL Kazakhstan KAZ Botswana BWA Kazakhstan KAZ1 Brazil BRA Latvia LVA Bulgaria BGR Lithuania LTU Canada CAN Mal
General Information EBA-03 Bill Validator Section 1 Table 1-1: Country Code Listings (Continued) Country Country Code Russia RUS Russia RUS-B Saudi Arabia SAU Singapore SGP Singapore SGP-B Slovakia SVK Slovenia SVN South Africa ZAF Spain ESP Sri Lanka LKA Sweden SWE Switzerland CHE Switzerland CHE3 Switzerland CHE-B Taiwan (Republic Of China) TWN Tanzania TZA Thailand THA Trinidad & Tobago TTO Ukraine UKR Ukraine UKR1 United Arab Emirates ARE United States USA
EBA-03 Bill Validator THIS PAGE INTENTIONALLY LEFT BLANK JCM Part No. 960-000058R_Rev.
EBA-03 Bill Validator Bill Acceptor Series Section 2 2 INSTALLATION / OPERATION • DIP Switch Settings • Preventive Maintenance. This section provides installation and operation instructions for the EBA-03 Bill Validator. The information within contains the following features: Figure 2-1 illustrates a typical EBA-03 system connection. • Pin Assignments Connections Figure 2-1 Typical EBA-03 System Connections JCM Part No. 960-000058R_Rev.
Section 2 EBA-03 Bill Validator Installation / Operation Pin Assignments Table 2-1 Serial I/F (ID-044C) Pins Assignments Pin Signal No.
Installation / Operation EBA-03 Bill Validator Section2 Table 2-4 Pulse I/F (ID-003) Pin Assignments CPU Board 9 1 10 2 Pin No.
Section 2 EBA-03 Bill Validator Preventive Maintenance Table 2-5 DIP Switch 1 (DS-1) Settings It is important to keep the bill path, rollers, and belts clean. The sensor lenses are transparent surfaces, and are made of a polymer material. Handle them with extreme care. NOTE: Turn DS-1, Switch #1 ON to enter the test mode. DIP Switch No.
EBA-03 Bill Validator Bill Acceptor Series Section 3 3 DISASSEMBLY / REASSEMBLY Remove Four Cover Securing Screws Lift Cover Off This section provides disassembly and reassembly instructions for the EBA-03 Bill Validator. The information within contains the following features: • Disassembly Procedure • Reassembly Procedure Disassembly Procedure To correctly disassemble an EBA-03 unit, perform the following steps: 1.
Section 3 EBA-03 Bill Validator Disassembly / Reassembly Lift the Board Up and Off the Frame a Figure 3-6 CPU Board Removal Figure 3-9 Lower Sensor Board Cover Removal 14. Remove the two screws securing the motor cover from the lower assembly and remove the motor, gears and drive belts from the assembly (See Figure 3-10 a). a Figure 3-7 Sensor Cover Screw Removal 10. Remove the Sensor Cover by removing the two retaining screws shown in Figure 3-7 a. a 11. .
EBA-03 Bill Validator Bill Acceptor Series Section 4 4 CALIBRATION Connecting a PC for Calibration Figure 4-1 illustrates the required equipment inter-connection necessary to properly calibrate the EBA-03 unit. Figure 4-1 EBA-03 Test Setup Figure 4-2 illustrates the required tools necessary to properly calibrate the EBA-03 unit. Figure 4-2 EBA-03 Test Tool Requirements Installing the Calibration Software VM-450 and EBA-03 DIP Switch Settings 1.
Section 4 EBA-03 Bill Validator Calibration Figure 4-5 Second Software Install Screen Figure 4-8 Final Adjustment Software Screen 3. Click the Screen Button to continue the installation. 3. Then click on the Screen Button. When that test is finished, replace the White Reference Paper with the Black Reference Paper (Part No. 074542). 4. To complete the software installation on your hard drive, click the large icon shown in Figure 4-6 and follow the screen prompts. NOTE: This test only takes a second.
Calibration EBA-03 Bill Validator Section 4 Table 4-1 Error Codes (Continued) Error Name Sensor Name r3u_ir R3UI r3u_rd R3UR l1t_rd L1UR/PTL1 r1t_rd l2t_gn R1DR/R1PT L2DG/L2PT r2t_gn R2UG/PTR2 b0t_ir BIR/BPT f0t_ir e0t_ir FIR/FPT EIR/PTE s0t_ir SIR/SPT Figure 4-9 Sensor Locations Refer to Appendix A for additional sensor troubleshooting procedures. JCM Part No. 960-000058R_Rev.
EBA-03 Bill Validator THIS PAGE INTENTIONALLY LEFT BLANK JCM Part No. 960-000058R_Rev.
EBA-03 Bill Validator Bill Acceptor Series Section 5 5 EXPLODED VIEW AND PARTS LIST This section provides exploded view and associated parts lists for the EBA-03 Bill Validator. EBA-03 Exploded View Figure 5-1 EBA-03 Exploded View JCM Part No. 960-000058R_Rev.
Section 5 EBA-03 Bill Validator Exploded View and Parts List EBA-03 Parts List Table 5-1 EBA-03 Parts List No. EDP No. Part No. 1 067383 659-3110-06-01B-02 CPU Board Assy. 1 2 3 067382 067412 659-3110-06-02B-01 659-3110-05-01A-01 Sensor Board Assy. Regulator Module Assy. 1 1 4 5 067416 067489 659-3110-05-02A-01 3110-05-03B DC Motor Module Assy.
EBA-03 Bill Validator Bill Acceptor Series Section 6 6 INDEX T B Test of acceptor functions… A-23 of acceptor interface… A-23 of bill acceptance… A-23 Bill Acceptor general information concerning the… 1-1 Bill jam Tests BSY Troubleshooting motor rotation… A-22 removing a… A-21 instructions for… A-21 VM-450 Tests for… A-21 busy LED… A-21 C W Caution Warning against currency note testing… A-22 small ball against use of solvents… 2-10 regarding cleaning solution types… 2-10 … 3-12 possibl
Section 6 EBA-03 Bill Validator INDEX THIS PAGE INTENTIONALLY LEFT BLANK JCM Part No. 960-000058R_Rev.
EBA-03 Bill Validator Bill Acceptor Series Section A A TROUBLESHOOTING This section provides troubleshooting instructions for the EBA-03 Bill Validator. The information within contains the following features: • • • • • Removing a Jammed Bill Performance Tests Test DIP Switch Settings Troubleshooting Using VM-450 Tests Error Codes Figure A-2 Connecting the Ribbon Cable 2. Connect the AC Power Cord supplied in the kit to the VM-450 to a suitable power source. 3.
Section A EBA-03 Bill Validator TEST NO. 1 TRANSPORT MOTOR FORWARD ROTATION TEST The first test is the motor speed test in a forward direction. described lights on the VM-450 will indicate the motor speed rate (Review Figure A-5). TEST NO. 3 ACCEPTOR SENSOR TEST This test checks the acceptor head sensors status. 1. Set the initial DIP Switches according to the Figure A-4 illustration. 2. With the power turned off to the VM-450, set DS-1, Switch #1 to the ON position.
EBA-03 Bill Validator SectionA 1. Set the initial DIP Switches according to the Figure A-12 illustration. Figure A-12 Acceptor Function Test DIP Switch Settings 2. Turn off power to the VM-450. 3. Set DS-1, Switches #1, #2, #3, and #4 ON. 4. Turn on power to the VM-450 and change DS-1, Switch #1 to OFF to begin running the tests. If an error occurs during the test operation, the ABN LED on the VM-450 will light and the test operation will stop. Figure A-9 Sensor “F” Detection Lit LED TEST NO.
Section A EBA-03 Bill Validator If the Acceptor does not accept a bill, count how many times the Red LED flashes to determine the possible malfunctions requiring correction (See Table A-2 in Error Codes on this page). Table A-3 Green LED Rejection Codes No. of Green LED Flashes Error Description 1 Crooked Bill Insertion If the Acceptor rejects a bill, count how many times the Green LED flashes to determine the possible malfunctions requiring correction (See Table A-3 in Error Codes on this page).
EBA-03 Bill Validator Bill Acceptor Series Appendix B B GLOSSARY A 1 2 ABN – acronym for Abnormal. Acceptor – a term used in Communications Section 3 referencing functions sent to, and received from the Coin Acceptor by software commands. C 3 4 5 6 ACK – abbreviation for Acknowledge. Country Codes – specific codes given to a country to identify its currency type. CPU – acronym for Central Processing Unit. CPU Board – a printed circuit board located at the top of the EBA’s transport section.