Specifications

CAUTION
Door is equipped with lockable Safety Door Latch.
Door should be closed and latched during operation
to prevent accidental interruption of operation from
doors being opened. Door Latch should be Locked-
Out and Tagged during servicing to prevent machine
from being powered up.
2. Turn Master ON/OFF Switch to OFF position
and open Door. (Door WILL NOT open unless
Master ON/OFF Switch is in OFF position.)
3. Open Door to enclosure.
WARNING
You must use the hole provided. Drilling any new
holes in the electrical enclosure may void the
warranty.
4. Remove hole plug located on top, left side of the
enclosure. Then install an oil tight fitting.
5. Insert Electrical Supply Cord through Oil Tight
Fitting and route to Electrical Disconnect Block.
6. Strip 254 mm (10 in) off cable's outer jacket.
7. Strip 6 mm (1/4 in) of insulation off each wire.
8. Connect Green Wire (GRN) to Terminal PE on
Electrical Disconnect Switch (Earth Ground).
9. Connect other three wires to Disconnect Block
(1DISC) as noted on Block (L1, L2, L3).
10. Route and secure Cord inside of Enclosure.
11. Tighten Oil Tight Fitting.
12. Close and secure/lock Door to Enclosure.
13. Route and connect Electrical Supply Cord to
factory main power source.
14. Turn ON Master ON/OFF Switch.
COOLANT SYSTEM (Optional)
The machine comes with a Sump Pump and a small
Reservoir. Because of the numerous application
possibilities the machine is not supplied with a coolant
system, optional Coolant Systems are available.
Placement and system requirements will vary with
coolant system used. Sunnen provides several optional
coolant systems (
see Figure 1-8). Check with your
local Sunnen Field Service Engineer or Sunnen
Products Company Technical Services for available
systems or before installing another manufacturer's
system.
IMPORTANT
Operating Instructions and Repair Parts Catalogs for
the optional Coolant Systems are supplied by the
systems manufacturer.
Fill Coolant Reservoir with either Sunnen Industrial
Honing Oil or Sunnen Water-Based Coolant.
Refer
to Section 4.
COOLANT SYSTEM CONNECTION
The machine comes with a Sump Pump and a small
Reservoir. Intake and Outlet Hose Barbs are provided for
connecting optional Coolant System (
see Figure 1-8):
CAUTION
Supply coolant pressure should not exceed 20 psi
(0,14 MPa).
MAGNETIC SEPARATOR (Optional)
Like the Coolant System, the machine is not supplied
with a magnetic separator (
see Figure 1-9). If your
application produces large amounts of metal residue, it
is recommended that you employ either or both a
magnetic separator and filter system. Check with your
local Sunnen Field Service Engineer or Sunnen
Products Company Technical Services for available
options or before installing another manufacturer's
system.
SPECIAL FIXTURE (Optional)
Because of the numerous applications possibilities the
machine is not supplied with any fixturing, optional
fixtures are available (
see Figure 1-10). Check with
your local Sunnen Field Service Engineer or Sunnen
Products Company Technical Services.
4
FIGURE 1-10, Universal Fixture
UNIVERSAL
FIXTURE
FIGURE 1-9, Magnetic Separator
INTAKE
MAGNETIC
SEPARATOR