User`s guide

CDA 7 Maintenance Manual
C-20 77 A7 48UU Rev03
SA-16: (4 Channels)
Channel: A
1st dev | last dev | 1st chn | last dev | count |
======== | ======== | ======== | ======== | ======== |
000 | 07 | 20 | 27 | 8 |
Channel: B
1st dev | last dev | 1st chn | last dev | count |
======== | ======== | ======== | ======== | ======== |
Channel: C
1st dev | last dev | 1st chn | last dev | count |
======== | ======== | ======== | ======== | ======== |
Channel: D
1st dev | last dev | 1st chn | last dev | count |
======== | ======== | ======== | ======== | ======== |
================== System IDs ==================
00 | 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 0A | 0B | 0C | 0D | 0E | 0F |
==================================================================
E0 | E0 | E0 | E0 | E0 | E0 | E0 | E0 |
This shows a configuration with 16 Mirrored disks, and 4 SCSI Channel
DIRECTORS.
C.3.7.4 Modifying the Configuration
If the configuration is incorrect, there are several solutions:
The Bull Competence Center download your IMPL.New file.
The Bull Competence Center may be present at the installation and have the
diskette containing standard files.
If necessary, copy the file under MS-DOS using the following procedure:
1. Press Escape to exit from the main menu. The C:\SYMM4 prompt is
displayed.
2. Rename the IMPL.Bin file as IMPL.Old.
3. Copy the IMPL.Bin file.:
4. Return to the main menu:
C:\SYMM4 > LOOP