- Kitchen Appliance Manufacturer Range User Manual

33
Provision for Ventilation
The appliance should be installed into a room or space with an air supply in accordance with BS 5440-2:
2000.
For rooms with a volume of less than 5m
3
- permanent ventilation of 100cm
2
free area will be
required.
For rooms with a volume of between 5m
3
and 10m
3
a permanent ventilation of 50cm
2
free area will be
required unless the room has a door which opens directly to the outside air in which case no permanent
ventilation is required.
– For rooms with a volume greater than 10m
3
- no permanent ventilation is required.
Note: Regardless of room size, all rooms containing the appliance must have direct access to
the outside air via an openable window or equivalent.
Where there are other fuel burning appliances in the same room, BS 5440-2: 2000 should be consulted
to determine the correct amount of free area ventilation requirements.
The above requirements allow also for use of a gas oven and grill but if there are other gas burning
appliances in the same room, consult a qualified engineer.