CIGE9 Extractors Manual for Installation, Use and Maintenance Passionate about style Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.
Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that CDA reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment.
Using your Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. A - Light switch B - Power indicator light C - Power switch A A1 A2 B C C1 C3 Fig. 1 C2 C4 To switch the extractor light on or off • Slide the light switch to position A1 for off, or A2 for on.
Care and Maintenance IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. Cleaning You should use a non-abrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. You can clean you extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth, for example the CDA E-Cloth.
Changing the Light IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO COOL BEFORE REMOVING IT. 1. Remove the grease filters as described above. 2. Remove the faulty light bulb and replace with a light bulb no more powerful than that specified on the rating plate. 3. Replace the grease filters.
Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.
Installation IMPORTANT: The extractor is intended to be mounted directly to the ceiling using fixings appropriate for the ceiling. Ensure that there is adequate ceiling strength and supports at the fixing points; if in doubt, consult a joiner or electrician.
Installation To fix your extractor to the ceiling, proceed as follows 1. Mark the fixing positions of the wall plugs that will be used to secure your extractor to the ceiling, as shown in fig. 4 2. Drill 4 holes and insert the wallplugs, ensuring that they are suitable for use with your ceiling. If the extractor is to be fixed directly to ceiling joists then wall plugs may not be required. 191 203 Fig.4 3. Fit the vent adaptor (G) to the body of the extractor, using the 2 self-tapping screws. E 4.