EVG Extractors Manual for Installation, Use and Maintenance Passionate about style Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.
Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that the manufacturer reserves the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment.
Using your Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. Control Panel A - Light key B - Decrease speed key C - Display D - Increase speed key E - Timer key Fig. 1 A B C D E To switch the extractor light on and off • Touch key A. To switch on the extractor • Touch either key B or D. The appliance will switch on at the first speed. • To increase the speed touch key D.
Care and Maintenance IMPORTANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. 1 Cleaning You should use a nonabrasive cleaner. Any abrasive cleaner (including Cif ) will scratch the surface and could erase the control panel markings. 2 You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth. Fig.
Changing the Light IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO COOL BEFORE REMOVING IT. Carefully prise open the lamp assembly cover (D) using a small, flat-bladed screwdriver and remove the old bulb (C). Refit the new bulb taking care not to touch the glass of the bulb (Fingerprints will lead to premature failure of the bulb) C Fig.
Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.
Installation Your extractor can be used to filter and recycle the air within your kitchen, or to extract the air outside. When extracting air to the outside, the unit can be vented as shown in the diagram below. Note that we recommend the use of ducting with a diameter of 150mm. Ducting with diameters of 100mm or 120mm may be used, but performance will be reduced. When installing this appliance over a CDA hob, the clearance between the extractor and the hob must be equal to or exceed 450mm.
Installation The extractor is mounted using four screws. Ensure that the wall fixings and screws are suitable for the wall material. Mark the positions of the four holes on the wall, according to fig 8. 133mm Insert the 4 wall plugs into the holes and fix 2 screws in the top holes so that they are protruding from the wall by approx 5mm. 148mm Next, lift the hood onto the 2 screws as shown in the diagram (fig 9).
Using the extractor as a recirculation device Refit the top cover and grill as below before proceeding to fit the charcoal filter – Locate each filter onto the motor housing spigot and rotate to lock into position as shown in figure 12. Mounting the Chimney Section 1. Adjust the width of the mounting bracket to suit the chimney size of your extractor and mark 2 points on the wall, 20mm down from the ceiling for the fixings (fig 13). Fig. 12 20 2.
Installation Finally, fit the ducting adapter to the extractor outlet and secure the chimney to the body of the extractor as shown in figures 15 and 16. Fig. 15 Fig.
Fiche Attribute Model Identification Annual Energy Consumption Time increase factor Fluid Dynamic Efficiency Energy Efficiency Index Measured airflow at Best Efficiency Point Measured Pressure at Best Efficiency Point Maximum airflow Measured electric power at Best Efficiency Point Nominal lighting power Average illumination of the lighting system on the cooking surface Measured power consumption in standby Measured power consumption off mode Sound power level Grease Filter Efficiency Lamp efficiency Symbo
To contact our Customer Care Department, or for Service, please contact us on the details below. Passionate about style Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.