Operating instructions

Preventive Maintenance Manual
144 Copyright © 2012 EVG
11.1 EVG520
Purpose / Type Dia./
Size
Volume / Specification
OD:
8 mm
(3/8”)
8 bar (Minimum) – 10 bar
(Maximum)
Nitrogen or compressed air
(dried, cleaned):
Flow rate:
30 Liter/min (63,5 ft³/h)
Cooling water:
ID:
13mm
Pressure: 3 - 5 bar (44 - 73 psi)
Flow rate: > 9 Liter/min
Power requirements:
Maximum power input: 9.1kW (150mm heater
configuration)
13.9kW (200mm heater
configuration)
Fuse rating: European system: 35 Ampere
(Fuse Type: slow)
US/Japan system: 63 Ampere
(Fuse Type: slow)
Heat load for EVG520: 150mm heater with active topside
cooling 6.5 kW
150mm heater without active
topside cooling 4.5 KW
200mm heater with active topside
cooling 8.5 KW
200mm heater without active
topside cooling 5.5 KW
Weight (machine): 665 kg
351 of 370