5.17.1.1 Adjust Endswitches – Bottom Cooling
Figure 122 - Endswitches for "Cooling Bottom ON/OFF"
1 Cooling Bottom ON
2 Cooling Bottom
OFF
If it is not possible to reach the two end switches (Figure 123 –
Endswitches for “Cooling Bottom ON/OFF”; 1 and 2) for any
adjustments, it is necessary to dismount the bond module (loosen the
two fastening screws).
Caution: Do not peg out the connectors. The functions of the end switches will
only work with all connections and on-state!
Readjust the end switch for “Cooling Bottom Off” (this is the end switch
in the lower position). For this loosen the fastening screw and turn the
cooling to “Cooling Off”. Toggle the end switch as long as you can see
the LED on and off. Find the position where the LED in upper position is
just about ON.
Turn the cooling to “Cooling ON” for testing. The LED at the new
adjusted end switch must be OFF now.