Operating instructions
Preventive Maintenance Manual
94 Copyright © 2012 EVG
7) Open the “Jobs” –window in the system software. Point with the
mouse onto the Chamber –symbol and press left mouse button to
open the additional menu for the chamber. Go to “Piston” and
press button “Set Piston Force”.
Figure 96 - Load Cell Test - Set Piston Force
8) Enter the force into field “Setpoint” and press “OK” to confirm.
Figure 97 - Load Cell Test - Enter Piston Force
9) Start measurement. Sum up the three values [kN] on the display of
the measuring tool and compare with the Setpoint.
10) Remove the measuring gauge and the load cell with caution. Don’t
forget to install the screw shown in Figure 93 – Remove screw.
301 of 370