Weekly Maintenance
Copyright © 2012 EVG 69
4
4
Figure 60 - Pressure Film Test Result
Place the bond chuck in the chamber and apply a piston force
according to the table below. After 30sec of delay release the piston
force and remove the tool from chamber. Unclamp the substrate
manually and remove the top wafer + top pressure film carefully. You
can see the result of the pressure film test on the bottom pressure film.
Required Contact Force for Pressure Film 28 – 85PSI (19,31 –
58,61N/cm²)
Wafersize 100mm 150mm 200mm 300mm
min. Contact Force 1525N 3400 6060 13650
max. Contact Force 4600N 10400 18500 41600
276 of 370