Operating instructions

Preventive Maintenance Manual
48 Copyright © 2012 EVG
Pneumatic connections on the cylinder
Figure 43 - Pneumatic Connections
1 Connect the “down” line at the wafer bow
quick connector.
Bleeding the system
Follow existing routine to bleed the hydraulics.
Note: The “piston up” circuit does not exist anymore.
For easier bleeding disconnect the pneumatic “up” and “down” line while the
piston is in upper position.
Loadcell test and adjustment
A loadcell-test including piston-force calibration is strongly
recommended after the installation of the new hydraulic-cylinder unit.
1
255 of 370