Schematics without backpressure control
Figure 32 - Hydraulic System without backpressure control
Note:
Pneumatic cylinder inside the hydraulic cylinder assembly uses a “piston up”
pressure of 6bar. The pressure-converter uses a pressure of 2bar only.
The separation-tank is connected to the hydraulic-cylinder and the pressure
converter through 2 independent leak lines.