7) Fill the funnel with hydraulic fluid and open the shutoff-valve.
8) Now connect a short hose on the lower screw of the pressure head
(picture below), open it one rotation and wait again until the fluid
comes out without any bubbles. Then tighten the screw and close
the shutoff valve.
Figure 29
9) Remove hose and funnel and reconnect the blue hose to the
shutoff valve.
10) Move the Piston UP.
243 of 370