Operating instructions

Weekly Maintenance
Copyright © 2012 EVG 33
4
4
4.3.1.5 Filling / Bleeding the hydraulic system
Figure 25
Filling bleeding of the upper hydraulic circuit
1) Press Piston up button
2) Open the pressure cover. Again make sure the piston is in its
upper position and the piston up pressure-regulator is set to 2 bar
(200kPa).
3) Close cover.
4) Make sure, enough hydraulic fluid is in the header-tank. (Filling
level should be above the filling-level sensor)
5) Connect short hose to the upper screw on the pressure-head (see
drawing above or picture below) and open the screw 1 rotation
counterclockwise. Wait till the hydraulic fluid comes out without any
air-bubbles.
Figure 26
6) Tighten the screw again and remove the hose.
7) Refill hydraulic fluid in the header-tank if necessary.