Operating instructions

Bond Module
46 Copyright © 2013 EVG
4.3.5.2 Wait Current
With the wait current command the system will check if the current
passes the limit downwards (lower than) or upwards (higher than),
according to the defined value in the field “Target Current”.
Figure 38 - Wait Current
Value
Description
Mode
Enter the wait mode.
Current
Enter the target current.
Timeout
Activate timeout.
Deadline
Enter a timeout value. It defines the maximum allowed wait time
for the current setpoint. It will be reached until the error recovery
action is activated.
RecoveryAction
Choose the error recovery action.
It is recommended to use the Timeout feature only in well-known and
often used processes. The command is not useful for R&D processes
as long as parameters are changed often. The risk that the system
stops the process because of a wrong Timeout is high.
178 of 370