Operating instructions
Recipe Programming
Copyright © 2013 EVG 35
4
4
4.3.2 Vacuum System
Most wafer bonding processes require to be performed under vacuum.
The vacuum system recipe steps allow evacuating and/or purging the
bond chamber or waiting until a certain vacuum is reached in the bond
chamber.
4.3.2.1 Evacuate
With this recipe command the evacuation of the bond chamber can be
started or stopped.
Evacuate Low:
Evacuates the chamber only with roughing pump and without switching
to the Turbo Molecular Pump.
Evacuate High:
Evacuates the chamber with the roughing pump and switches to the
Turbo Molecular Pump later on.
Evacuate Off:
Stop evacuation of the chamber (close valves).
Figure 28 - Evacuate
Value
Description
Mode
Select the evacuate mode.
Setpoint
Enter a setpoint for the pressure in the chamber.
167 of 370