1.4.3 Facility Problems
1.4.3.1 Missing Water Flow
If the water flow is missing a timer will be started (standard: 2 minutes)
and a message box will appear on the screen. Click on “OK” to confirm
the message box.
In the meantime the chamber will continue processing but the handling
will be paused.
Water flow resumes in time:
Water flow does not resume in time:
If the water flow resumes within the
time set, the message box has to be
confirmed by the user.
If the water flow does not resume within
the time set, all heaters will be shut down
and the process will be aborted.
Note: The message box has to be confirmed even if the water flow resumes in
time! Otherwise the process could be paused at some point until the message
box is confirmed.
1.4.3.2 Missing CDA
If the CDA pressure is missing a timer will be started (default: 2
minutes, maximum: 5 minutes) and a message box will appear on the
screen. Click on “OK” to confirm the message box.
In the meantime the chamber will continue processing but the handling
will be paused.
CDA pressure resumes in time:
CDA pressure does not resume in time:
If the CDA pressure resumes within
the time set, the message box has to
be confirmed by the user. The handling
will resume.
If the CDA pressure does not resume
within the time set, the process will be
aborted.
Note: The message box has to be confirmed even if the CDA pressure resumes
in time! Otherwise the process could be paused at some point until the
message box is confirmed.