Specifications
19
E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the
right to change speciļ¬cations without prior notice.
Attribute Symbol Units
Model Identification edd61 edd91
Annual Energy Consumption AEC
Hood
54.0 49.6 kWh
Time increase factor f 1.0 0.9
Fluid Dynamic Efficiency FDE
Hood
26.5 (B) 30.2 (A)
Energy Efficiency Index EEI
Hood
55.8 50.4
Measured airflow at Best Efficiency
Point
Q
BEP
317.0 344.0
m
3
/h
Measured Pressure at Best Efficiency
Point
P
BEP
446.0 477.0 Pa
Maximum airflow Q
MAX
636.0 757.0
m
3
/h
Measured electric power at Best
Efficiency Point
W
BEP
148.0 151.0 W
Nominal lighting power WL 0.0 0.0 W
Average illumination of the lighting
system on the cooking surface
E
Middle
0.0 0.0 Lux
Measured power consumption in
standby
P
S
0.5 0.5 W
Measured power consumption off
mode
P
O
0.0 0.0 W
Sound power level L
WA
69.0 61.0 dBA
Grease Filter Efficiency GFE
Hood
61.1 (E) 63.0 (E) %
Lamp efficiency LE
Hood
0.0 0.0 %
Fiche
Value