Specifications

27
Electrical Installation
For your safety please read the following information:
WARNING! Before eecting any intervention on the electrical parts the appliance must be disconnected
from the network.
IMPORTANT: The oven must be installed in accordance with the manufacturer’s instructions.
Incorrect installation, for which the manufacturer accepts no responsibility, may cause damage to
persons, animals and things.
General
• The connection to the electrical network must be carried out by qualied personnel and must be
according to existing norms.
• The appliance must be connected to the electrical network verifying above all that the voltage
corresponds to the value indicated on the specications plate and that the cables section of the electrical
plant can bear the load which is also indicated on the plate.
• The appliance can be connected directly to the mains placing an omnipolar switch with minimum
opening between the contacts of 3 mm between the appliance and the mains.
• The power supply cable must not touch the hot parts and must be positioned so that it does not exceed
75°C at any point.
• Once the appliance has been installed, the switch must always be accessible.
• If the power supply cable is damaged it must be substituted by a suitable cable.
IMPORTANT: this double oven must be connected to a suitable double pole control unit adjacent to the
oven.
NO DIVERSITY CAN BE APPLIED TO THIS CONTROL UNIT.
Feeder Cable Section
Type H05RR-F or H05VV-F
230 V~ 3 x 2,5 mm
2
(**)
(**) - Connection to wall-mounting distribution panel.
The connection of
the appliance to the
grounding unit is
mandatory.
The manufacturer
declines every
responsability for
any inconvenience
resulting from the
inobservance of
this condition.