Specifications
23
Installation
Important
• You need the following housing area to t your oven correctly.
• The double oven is designed to t into a cabinet of 600 mm width.
• The double oven can be built in the kitchen units, but you must ensure that it is properly ventilated.
• Lift the appliance into position onto the shelf, taking care NOT to lift it by the door handles.
• Remember the housing should not be free standing but be secured to the wall and/or adjacent ttings.
WARNING
• We would point out that the adhesive which bonds the plastic laminate to the furniture must withstand
temperatures not less than 150° C to avoid delamination.
• The appliance must be housed in heat resistant units.
• The walls of the units must be capable of resisting temperatures of 75 °C above room temperature.
Product and Cabinet Dimensions (mm)
A overall height* of product 1077
B overall width of product 595
C overall depth of product (excluding handle and knobs) 567
D height of chassis 1057
E width of chassis 556
F depth of chassis 545
G
depth of oven frame and control panel
(=distance between front of chassis and front of oven door, excl. knobs)
22
I minimum inside width of cavity 560
I’ overall width of cavity 600
J inside height of cavity 1065
J’ overall height of cavity 1082
K minimum inside depth of cavity 550
L ush tting cabinetry clearance 22
* All height measurements include mounted feet.