Specifications

51
A
B
C
P
D
Green
&
Yellow
(Earth)
Brown (Live)
Blue (Neutral)
Fig. 9.1
Fig. 9.2
WARNING: This appliance must be earthed
CONNECTING THE DOUBLE OVEN MAINS CABLE
Unscrew the screws A securing the cover plate B behind the oven (fig. 9.1).
Remove the cover plate B.
Remove the screws C from the cable clamp (fig. 9.2).
Insert the mains cable (type H05RR-F or H05VV-F - 3x2,5 mm
2
section) into the cable
protector P.
Connect the phase and earth cables to the mains terminal connection block D.
EARTH
N NEUTRAL
L LIVE
Attention ! Make sure the wires have been well inserted into the contacts and
have been screwed down well.
Refit the cable clamp so that it clamps the outer sleeving of the cable, and screw
the screws C.
Refit the cover plate B and fix it with the screws A.