User`s manual
IL-F300 System Description
Doc. Man IL-F300 Vers. 1.02 ©2008 InnoLas GmbH Page 12
Manual Sensor Teaching via Two-Point Tuning
You must teach the sensor for wafer recognition.
Take care that the beam spot size
is already
adjusted and no wafer is on the Flipper.
Maybe you must de-activate the key lock first.
To de-activate the key lock press the MODE
(1) button together with the „up“ or „down“
(3) button for about 3 seconds respectively
until „un L“ starts flashing in the display to
deactivate the key lock.
Push the SET button (4) untill you get a steady
display.
Lay a wafer exactly on to the Flipper clamps.
Push the SET button (4) again untill you get
steady display.
Sensor teaching is now complete.The red display
(2) shows the current reflection intensity. The
green display (5) shows the automatically
calculated threshold between wafer present and
wafer not present (no display during calculation).
For more information refer to the Keyence manual
.
Sensor Teaching via Software
With InnoLas Sorter C3800 systems service
personnel can teach the wafer recognition for the
sensor via software. Take care that the beam spot
size is already adjusted.
To teach the sensor via software the key lock of the
amplifier must first be activated.
Warning!
LASER Radiation
Class 2 LASER product. Do not stare into beam!
Warning!
LASER Radiation
Class 2 LASER product. Do not stare into beam!
ILF 300 1-18 Flipper LASER Sensor Amplifier
Pic. ILF 300 Bild 15
5
2
1
3
4