Specifications
B-field Exposure From Induction Cooking Appliances 60
Figure 46: Appliance 3 and pot 3 (large pot, standard set of pots), front side of
the appliance. Comparison of the B-field with pot a) to e) centered, and f) to h)
non-centered: In Graphs a), b), c), d), f) and g), the B-field is measured in the vertical plane
(y, z), at measuring distances of 1, 5, 10, 30, 1 and 30 cm, respectively. In Graphs e) and h), the
B-field is measured in the horizontal plane. Other measuring conditions according to EN50366.
sides, pot centered) and 50 µT, 60 µT and 60 µT (rear, left and right sides, pot non-centered).