Specifications
B-field Exposure From Induction Cooking Appliances 56
Figure 43: Appliance 2, multi-hob measurement using the standard set of pots with
pots non-centered (front side of the appliance): The B-field is measured in the vertical
plane (y, z), at measuring distances of a) 1 cm, b) 5 cm, c) 10 cm and d) 30cm. Hobs 1, 2, 3 and
4 are switched on simultaneously (multi-hob measurement), using the standard set of pots (pots
14a, 3, 14b and 13 on hobs 1, 2, 3 and 4, respectively); other measuring conditions according to
EN50366.
respectively). The B-field does not exceed the ICNIRP limit (6.25 µT) for a measuring distance
of 30 cm, according to EN50366.
Figure 45 a) (pots centered), as well as Figures e), f) and g) (pots non-centered) show that
the ICNIRP limit is exceeded for a measuring distance from 1 to 5 cm and 10 cm for a centered
and non-centered pots, respectively. The corresponding maximum rms-values of the B-field
measured are 8.5 µT and 13.2 µT (measuring distance of 1 cm).