B-field Exposure From Induction Cooking Appliances 30
Figure 21: Harmonics contribution, in [dB] (power spectrum, 10 dB per division). Graphs a) and
b), c) and d), e) and f) correspond to appliances 1, 2 and 3, with hobs 1, 2 and 1, respectively
(largest hobs).
Figure 22: Measured B-field exposure for different heat settings, for a) appliance 1,
b) appliance 2 and c) appliance 3. Measurements performed at the largest hob: hobs 1, 2
and 1 for appliances 1, 2 and 3, respectively, with pot 3 and lid, measuring distance of 5 cm and
max. heating setting. Other measurement conditions according to EN50366.