Specifications
B-field Exposure From Induction Cooking Appliances 17
Table 3: Measuring distances and corresponding probe-center/hob-center distances. According to EN50366, the measuring distance is
the distance between the surface of the appliance and the closest point of the sensor surface. The front, rear, left and right sides of the
appliances and the hob numbering are shown in Figure 6.
appliance 1 (Electrolux) front side rear side left side right side
hob 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
measuring distance [mm] 10 10 10 10
dist. probe/hob center [mm] 222.5 262.5 442.5 462.5 432.5 392.5 212.5 192.5 222.5 512.5 202.5 522.5 502.5 212.5 522.5 202.5
measuring distance [mm] 300 300 300 300
dist. probe/hob center [mm] 512.5 552.5 732.5 752.5 722.5 682.5 502.5 482.5 512.5 802.5 492.5 812.5 792.5 502.5 812.5 492.5
appliance 2 (Gaggenau) front side rear side left side right side
hob 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
measuring distance [mm] 10 10 10 10
dist. probe/hob center [mm] 252.5 262.5 462.5 482.5 427.5 417.5 217.5 197.5 222.5 522.5 222.5 522.5 532.5 232.5 532.5 232.5
measuring distance [mm] 300 300 300 300
dist. probe/hob center [mm] 542.5 552.5 752.5 772.5 717.5 707.5 507.5 487.5 512.5 812.5 512.5 812.5 822.5 522.5 822.5 522.5
appliance 3 (Inducs) front side rear side left side right side
hob 1 1 1 1
measuring distance [mm] 10 10 10 10
dist. probe/hob center [mm] 322.5 262.5 262.5 262.5
measuring distance [mm] 300 300 300 300
dist. probe/hob center [mm] 612.5 552.5 552.5 552.5