User manual

Product Description
Alarm/Sensor/PTZ Connection
Alarm
This product does not supply power to an alarm internally. The alarm
type that should be used is Dry Contact Type. Up to 1 alarm can be
connected.
G Use two wires for connection.
G Depending on type of Alarm used, please choose the right
type from DVR׏s Alarm Menu.
Info
NO
Normal Open
NC
Normal Close
Sensor
This product only supports sensors that act as simple mechanical
switches (dry-contact type sensors.) Up to 4 sensors can be
connected.
G Of the two wires from the sensor equipment, connect one of
the wires to the C (Common) terminal in the terminal block.
Then connect the other wire to the terminal of the
corresponding channel (1~4).
G Access the DVR Menu and setup each sensor to either NO /
NC.
PTZ
G Using RS485 Connection, PTZ cameras should be
connected using D+ and D- port in the rear of the system.
PTZ control signal can be daisy chained for multiple PTZ
devices
G Before using the PTZ, an appropriate PTZ protocol must be
selected in the PTZ menu.