User manual

14
Picture 4-2 Log onto matrix
If the log-in is abnormal, the following hints can be seen
“Communication failed, please re-log-inThe keyboard has not been
registered in the matrix or network communication has problems, please
check Network Management and Device Management in matrix, as
well as the network connections.
“Password error, please re-enterPassword verification failed, please
double-check and re-enter.
“User conflict, please re-enterThe user ID has been used on other
keyboard for logging into matrix, since one user cannot log-in from
different keyboards simultaneously, please use other user ID to log-in.
“User does not exist, please re-enterThis User ID has not been
registered in matrix, please register first through web.
“No assigned monitor, please change settings in matrixThere is no
monitor assigned to the subarea where the keyboard is assigned. Please
log onto matrix through WEB and change settings in matrix.
4.2 Matrix Operation Screen
Picture 4-3 Matrix Control Screen
1 Extended Function ButtonsOn both sides of the screen, Buttons named
F1~10 are extended function buttons. Functions of these buttons vary under
different status. Please refer to 8.1 Definition of Extended Function
Buttonsof chapter 8 for details.
2 Alarm PointPressALMto switch cursor to ALARM lineinput numbers
or pressPREV/NEXTto switch back and forth. Following icons are for
alarm arming, alarm triggering and alarm status. When alarm triggers, time
of alarm triggering will be shown beneath alarm point number.