User's Manual

4. Use 3/16th Allen Key (Series 5 Basic) or a Spanner to remove the Pump
Rod. On the Series 5 Basic the Pump Arm Guide Ring will come with it.
5. Inspect the o-rings on the Series 5 Basic’s Guide Ring or the Series 6
Guide Rod. If either is damaged, replace them. Lightly lubricate these o-
rings upon reassembly.
some heat to remove it. I have
never had to use heat, and this part never has to be removed, so be
careful and do not strip the bolt.
Series 5 Basic Pump Arm Guide Ring and o-rings.
6. Remove Vertical Regulator Adaptor (VRA). This is held on with red
Loctite® and thus you may need to use