User's Manual

21
TO CLEAR THE MAX/MIN RECORDS
Press and hold [ MAX / MIN ] key for 2 seconds to reset the current on display MAX or MIN records.
NOTE:
The LCD will also display the " " / " ", " " icon, data records time & date.
PAST 24 HOURS HISTORY DATA
The console automatically stores the weather data of the past 24 hours.
1. Press [ HISTORY ] key to check the beginning of the current hour's weather data, e.g. the
current time is 7:25 am, March 8, the display will show the data of 7:00am, March 8.
2. Press [ HISTORY ] key repeatedly to view older readings of the past 24 hours, e.g. 6:00am
(Mar 8), 5:00am (Mar 8), …, 10:00am (Mar 7), 9:00am (Mar 7), 8:00am (Mar 7)
NOTE:
The LCD will also display the " " icon, history data records with time & date.
WEATHER ALERT SETTING
Weather Alert can alert you of certain weather conditions. Once the alert criterion is met, the alarm sound
will activate and the alert icon on display will ash.
TO SET ALERT
1. Press [ ALERT ] to select and display the desired weather alert reading in the table below:
Alert Type Setting Range Display Section Default
Out Temperature High Alert
-40°C ~ 80°C
Out temperature &
humidity
40°C
Out Temperature Low Alert 0°C
Out Humidity High Alert
1% ~ 99%
80%
Out Humidity Low Alert 40%
In Current Channel Temperature
High Alert
-40°C ~ 80°C
In / CH temperature &
humidity
40°C
In Current Channel Temperature
Low Alert
0°C
In Current Channel Humidity
High Alert
1% ~ 99%
80%
In Current Channel Humidity
Low Alert
40%
Average Wind Speed 0.1m/s ~ 50m/s Wind direction & speed 17.2m/s
Feels Like High Alert
-65°C ~ 50°C
Weather index
20°C
Feels Like Low Alert 0°C
Dew point High Alert
-40°C ~ 80°C
10°C
Dew point Low Alert -10°C
Heat Index High Alert 26°C ~ 50°C 30°C
Wind Chill Low Alert -65°C ~ 18°C 0°C
UV index High Alert 1 ~16
UV & light intensity
10
Light intensity High Alert 0.01 ~ 200.0Klux 100Klux
Pressure Drop 1hPa ~ 10hPa Barometer 3hPa
Hourly Rainfall 1mm ~ 1000mm Rainfall 100mm
2. Under the current alert reading, press and hold [ ALERT ] key for 2 seconds to enter alert
setting and the alert reading will ash.
3. Press [
] or [ ] key to adjust the value or press and hold the key to change rapidly.
4. Press [ ALERT ] key to conrm the value.
5. Press [ ALARM ] key to toggle the regarding alert on / o󰀨.