Use and Care Manual

Refrigeration mode
• After power-on startup take refrigeration mode as default or press mode key to select
refrigeration mode, and refrigeration indicator lamp is on.
• Pressing UP/DOWN key can regulate setting temperature (17°C~30°C).
• Pressing air speed key can select high, medium or low air speed.
Air supply mode
• Pressing air speed key can select high or medium or low air speed.
• Temperature cannot be set.
Dehumidification mode
• Select dehumidification mode by pressing mode key or by means of remote control; and
humidification indicator lamp is on.
• At the beginning of entry into dehumidification mode, if the room temperature is 15°C (or 59°F),
compressor starts. After that control as the following rules: when the room temperature is 13°C
(or 55 °F), compressor shuts down; as the temperature rises again to the room temperature 15°C,
compressor restarts (3min time-delay protective function must be satisfied).
•In dehumidification mode, the fan runs at low speed in default and air speed cannot be regulated.
•Temperature cannot be set.
(Usage tip: for use of dehumidification function, exhaust pipe assembly should be removed,
otherwise the dehumidification effect becomes less obvious and flash alarm display of “FL” full
water appears.)
Auto mode
•Select auto mode by pressing mode key or by remote control; and auto indicator lamp is on.
•After selection of auto mode, the running states are determined in accordance with ambient
temperature: When the ambient temperature is over 25°C, the running state is the same as that in
refrigeration mode; while the ambient temperature is less than 25°C; the running state is the same
as that in air supply mode.
Timer mode
• In standby state, pressing TIMER key can set timer startup. Press UP/DOWN key to set timer
startup time (0~24h), and timer indicator lamp is on.
• In startup state, pressing TIMER key can set timer shutdown. Press UP/DOWN key to set timer
shutdown time (0~24h), and timer indicator lamp is on.
Operating method
11/12