User`s manual
User’s Manual
12
Switch no. Protocol Baud rate
00 VCL 9600
01 Pelco D 2400
02 Pelco P 4800
04 Chiper 9600
05 Philips 9600
07 GANZ-PT 9600
08 AD422 4800
09 DM P 9600
11 Pelco D 4800
12 Pelco D 9600
13 Pelco P 2400
14 Pelco P 9600
15 JVC 9600
16 GANZ-S 4800
17 GANZ-S 9600
18 GANZ-S 19200
19 GANZ-S 38400
21
KALATEL RS485
9600
22
KALATEL RS422
4800
*GANZ-PT is for ZC-PT series PTZ Camera. GANZ-S is for ZC-S series PTZ Camera.
For example, select protocol Pelco D with a baud rate of 2400, the ID switch should
be set as shown below.
Tens Units
NOTE: Change the PTZ Camera’s control protocol only when the camera is
powered off.
After changing protocol, please do the following procedure:
(1) Set SW 5(Communication switch) on.
(2) Power on the camera and check the message on the screen.
(3) Power off and set SW 5(Communication switch) off.