Use and Care Guide
Page 8
Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances. 
(Please consult with a qualied electrician for 220-Volt 50 Hz voltage)
It is the customer’s responsibility:
To contact a qualied electrical installer.
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/
NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 0-M91 
- latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician determine • 
that the ground path is adequate.
A 120-volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both • 
sides of the line.
Do not ground to a gas pipe.• 
Do not have a fuse in the neutral or ground circuit.• 
RISK OF ELECTRICAL SHOCK. This range hood must be properly grounded. Check with a qualied elec-• 
trician if you are not sure whether the range hood is properly grounded.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through exible • 
armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at 
each end of the power supply cable. Do not use extension cord or adapter plug with this appliance.
The range hood must be connected with copper wire/plug only.• 
Always use plug provided. If not possible, connect three wires according to its color (black to hot, white to • 
neutral, and green to ground) to house wires and cap with wire connectors:
Wire sizes  (copper  wire only) and connections  must  conform with the rating of  the appliance as specied on 
the  model/serial  rating  label.  Wire  sizes  must  conform  to  the  requirements  of  the  National  Electrical  Code 
ANSI/NFPA  70  —  latest  edition*,  or  CSA  Standards  C22.  1-94,  Canadian  Electrical  Code  Part  1  and  C22. 
2  No.    0-M91  -  latest  edition**  and  all  local  codes  and  ordinances. A  U.L.  -  or  C.S.A.  -  listed  conduit  con-
nector  must  be  provided  at  each  end  of  the  power  supply  cable  (at  the  range  hood  and  at  the  junction  box). 
Copies of the standards listed may be obtained from:
* National Fire Protection Association   ** CSA International
Batterymarch Park      8501 East Pleasant Valley Road
Quincy, Massachusetts 02269    Cleveland, Ohio 44131-5575
White
Green
Black