Installation Guide & User Manual
Use and Care Information
Operations:
Read and understand all instructions and warnings in this manual before operating the appliance. Save these •
instructions for future reference.
Always leave safety grills and lters in place. Without these components, operating blowers could catch on to •
hair, ngers and loose clothing.
NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.•
NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch re. The risk of •
self combustion is higher when the oil has been used several times.
NEVER cook on “open” ames under the range hood. Check deep-fryers during use: Superheated oil may be •
ammable.
Cleaning:
The saturation of greasy residue in the blower and lters may cause increased inammability. Keep unit clean •
and free of grease and residue build-up at all times to prevent possible res.
Filters must be cleaned periodically and free from accumulation of cooking residue (see • cleaning instructions
on Page 18). Old and worn lters must be replaced immediately.
DO NOT operate blowers when lters are removed. Never disassemble parts to clean without proper instruc-•
tions. Disassembly is recommended to be performed by qualied personnel only. Read and understand all
instructions and warnings in this manual before proceeding.
Page 15
Specications
1. In House Test Static Pressure “0”.
2. One sone is roughly equivalent to the sound of a refrigerator (1kHz) at 40 decibels.
3. Subject to change without notice, please contact your local reseller for details.
Specications
3
:
Body Design Seamless Stainless Steel, Satin Finish
Power Rating 220V/50Hz or 120V/60Hz (USA & Canada standard)
General Input Power # of Blower x360W + # of Light x20W + # of Heat Lamp x250W
Motor Input Power 360W per Blower
Levels Of Speed Control 4 / 6 Levels
Airow
1
1000CFM (Single Blower) / 1400CFM (Dual Blowers)
Noise Level
2
1.4Sone(45dB) to 8.0Sone(70dB) (Lowest to highest speed)
Number Of Motors Single or Dual Motor
Motor Type Dual Chamber Ultra Quiet
Fan Type Dual Centrifugal Squirrel Cage
Control Type Electronic Button or Touch Control Panel
Filtration Type Stainless Steel Bafe Filter
Illumination 35W Maximum, Dimmable
Heating Lamp 120V (USA & Canada) or 220V, 250W Maximum
Venting Size Top Transition Rectangular to 8 inches Round
Interference Protection Radio Frequency Interference Protected