120 Self-Flushing Self Washing Cat Litter Box - Manual Operation

CatGenie Tech has 6 Component Modes, which enable you to check if your CatGenie functions work or not. It also has 2 Test Modes.
By pushing the 2 Buttons on the Control Panel as directed, you can easily find what ails your CatGenie. Read before proceeding.
If you have any questions or are confused, please call us at 1-888-735-3927. Have your Serial # handy.
(Panel below indicates a #5 Tech Mode)
A. FIRST ACCESS TECH MODE
Lift the Processing Unit out of its slot, count to 3 and carefully put it back.
When you hear a series Beeps and 3 LEDs Blink, immediately press and HOLD Start
& Auto Buttons at the same time. Keep holding. Beeps & Blinks stop; but keep holding.
Then when a 2nd series of Beeps & Blinks activate, release both Buttons.
A 3rd series of Beeps & Blinks activates telling you that you are in Tech Mode
The #1 LED stays lit, telling you to proceed to the next step.
B. NOW ACCESS the individual COMPONENT MODE that relates to your specific problem. In Column One,
find Component (1 to 6) that applies and follow the directions across. NOTE:
*
indicates CAUTIONS. P&R indicates Press & Release.
CATGENIE TECH Only go here if directed from the Trouble Shooting pages
or when on the phone with a Customer Service Representative.
www.catGenie.com 1-888-735-3927
19
C. EXITING CATGENIE TECH
CatGenie Tech (Tech Mode) is active for 30 minutes. After 30 minutes, CatGenie reverts to normal operations mode. If you want to get out of
Tech Mode sooner,
lift the Processing Unit out of its slot, count to 3 and carefully put it back.
When you Activate 7, you get out of Tech Mode.
CAUTIONS:
*
Pay special attention when operating the Water Valve (fresh water in). If performing correctly, the CatGenie stops filling when water reaches
the Water Sensor. If not turned off, (see column 4 press START for OFF) filling resumes as soon as water level drops below the Water Sensor.
**
You must NOT leave the area while testing the Dryer. It is critical to pay attention while testing. Shut down if you must leave.
***
Do not over work Components1 through 6, as they could be damaged. These are only for diagnostic purposes.
CAUTION: Operate column 4, actions 1 through 6, at a maximum of no more than 30 seconds. After testing, make sure everything is OFF.
NOTE: Use the #7 Special Cycle when Granules are wet or damp as a result of poor or no draining from a clog.
TIP: Two LEDs help you navigate column 4 Actions: Cartridge LED indicates UP, ON, or RIGHT. Child Lock LED indicates DOWN, OFF, or LEFT
SHADED AREAS
SHADED AREAS
are only to be used with a Service Rep at 1-888-735-3927. Please call if you are unsure about any process.