Specifications

SEBU7858-03 115
Maintenance Section
Circuit Breakers - Reset
g01166347
Illustration 128
2. Remove latches (3) which hold the lter element
in place.
3. Remove the lter element. Clean the lter element
with pressure air or wash the lter element in warm
water. Use a nonsudsing household detergent.
Rinse the lter element in clean water and air dry
the lter element thoroughly.
4. After you clean the lter element, inspect the lter
element. Do not use a lter element with damaged
pleats or a damaged seal. If the lter element is
damaged, replace the lter element.
5. Install the lter element. Replace latches (3).
Reinstall the access cover.
Inside Filter
g01152478
Illustration 129
1. Remove latches (4) which hold the lter element
in place. Remove access cover (5).
2. Remove the lter element. Clean the lter element
with pressure air or wash the lter element in warm
water. Use a nonsudsing household detergent.
Rinse the lter element in clean water and air dry
the lter element thoroughly.
3. After you clean
the lter element, inspect the lter
element. Do not use a lter element with damaged
pleats or a damaged seal. If the lter element is
damaged, repl
ace the lter element.
4. Install the lter element. Reinstall access cover
(5). Replace
latches (4).
i02558339
Circuit Breakers - Rese t
SMCS Code: 1420-529
Circuit Breakers (Tractor)
g01229770
Illus
tration 130
The circuit breakers for the tractor are located at the
left s
ide of the operator's seat.
Circuit Breaker/Reset Push in the
butt
on in order to reset the circuit breaker. If
the electrical system is working properly, the
button will remain depressed. If the button does not
rema
in depressed, check the appropriate electrical
circuit. Repair the electrical circuit, if necessary.
Blower Motor (1) 20 AMP
Keyswitch (2) 10 AMP
Headlamp (3) (If Equipped) 15 AMP
Stop/Tail/Turn Lamp (4) (If E quipped)
10 AMP