4.3 Drill Operation
Page Procedure
Drill DOES NOT come out, Machine Routs, Clamp DOES NOT release:
□ Check Drill Solenoid for function or blockage…………………….. 40-41 21.51
□ Unclog Drill Solenoid………………………………………………… 38-39 21.50
Drill comes out and stays out as soon as air is attached…with
Machine power OFF:
Machine DOES NOT
finish cycle when carriage is pushed forward by hand:
□ Check Drill Motor is On……………………………………………… 33-34 21.40
□ Check Drill Stop Switch for function or adjustment………………. 37-38 21.43
Drill comes out and stops, Router cuts pocket and Clamp DOES NOT release:
Machine DOES finish cycle when carriage is pushed forward by hand:
□ Adjust Air pressure, may be too low……………………………….. 51-52 21.90
□ Check Drill Solenoid for function or blockage …………………….. 40-41 21.51
□ Unclog Drill Solenoid………………………………………………… 28-39 21.50
□ Check Router SQE Valve……………………………………………
(or Solenoid exhaust port ) for leakage
43-44 21.61
□ Check Drill SQE Valve……………………………………………….
(or Solenoid exhaust port ) for leakage
43-44 21.61
Drill bit not completing pilot hole into Pocket:
□ Adjust air pressure, Machine cycling too slowly………………….. 51-52 21.90
□ Bit mounted too deep into collet……………………………………. 34-35 21.41
Drill bit separating from the shank:
□ Adjust air pressure, Machine cycling too slowly………………….. 51-52 21.90
□ Bit mounted too deep into collet……………………………………. 34-35 21.41