Manual

Castle Inc TSM-21 Diagnostic Manual v2 Page 12 of 63
4.2 Router Operation
Page Procedure
Router doesn’t cut pocket…Machine Clamps and Drills, but Clamp DOES NOT release:
Check Router Feed Rate may be turned all the way down……... 31-32 21.32
Check Router Solenoid for function or blockage…………………. 30-31 21.31
Unclog Router Solenoid…………………………………………….. 29-30 21.30
Router Motor Operation…………………………………………….. 24-26 21.20
Check Router SQE Valve …………………………………………..
(or Solenoid exhaust port ) for leakage
43-44 21.61
Check Drill SQE Valve……………………………………………….
(or Solenoid exhaust port ) for leakage
43-44 21.61
Router doesn’t cut pocket… Machine Clamps, Drills and releases:
Check Router Stop Switch for function or adjustment…………… 27-29 21.22
Router comes up and STAYS UP as soon as air is atta
ched…..with Machine power OFF:
Check Router Solenoid for function or blockage…………………. 30-31 21.31
Unclog Router Solenoid…………………………………………….. 29-30 21.30
Router cuts pocket and STAYS UP, Drill doesn’t come out and Clamp doesn’t release:
Check Router Stop Switch for function or adjustment…………… 27-29 21.22
Router cuts pocket, Drill doesn’t come out and Clamp doesn’t release:
Check Drill Solenoid for function or blockage…………………….. 38-39 21.50
Router advances too aggressively:
Adjust internal Air Pressure………………………………………… 51-52 21.90
Adjust the Router Feed Rate……………………………………….. 31-32 21.32