Manual

Castle Inc TSM-21 Diagnostic Manual v2 Page 11 of 63
Page Procedure
Clamp releases slowly, Machine Routs and Drills:
Check Clamp cylinder and air line…………………………………. 19-20 21.12
Check Pilot Valve exhaust port……………………………………..
(up to machine sn: 61076 Only)
21-22 21.13
Check Pilot Valve for function or blockage………………………..
(up to machine sn: 61076 Only)
22-24 21.14
Check Clamp Solenoid for blockage………………………………. 11 21.10
Clamp doesn’t release…Machine Routs, and Drills:
Adjust internal Air Pressure………………………………………… 51-52 21.90
Check Pilot Valve for function or blockage………………………..
(up to machine sn: 61076 Only)
22-24 21.14
Check Drill Stop Switch……………………………………………... 37-38 21.43
Check Foot Switch…………………………………………………... 45-46 21.80
Clamp doesn’t release…Machine Routs, DOES NOT Drill:
Check Pilot Valve for function or blockage………………………..
(up to machine sn: 61076 Only)
22-24 21.14
Check Drill Solenoid for function or blockage…………………….. 40-41 21.51
Clamp doesn’t release…Machine Routs but Router DOES NOT retract, DOES NOT Drill:
Router Stop switch…………………………………………………... 27-29 21.22