Specifications

Castle Care-Tech Ltd Euro-MERiDIAN Getting
Software Page 51
APPENDIX:
Summary of Principal Programming
Options
MENUS SUMMARY
Menu
UK Default
Clean Start
-
Change Mode EoL
Enable ZEMs All disabled
Change Inputs All isolated
Assign Keypads/
Readers
Keypad 00=
enabled
System Displays Default text
Change Timers See page 34
Exit Modes Timed
Change Codes User=1234
M/Manager=2222
Engineer=1111
Volume Levels See page 39
Alarm
Responses
All
digi
Change outputs See page 40
Intelligent Set Off
Engineer Resets All Off
Site options -
Engineer Tests
-
Diagnostics
-
Program
Digimodem
Disabled
View Logs
-
INPUT TYPES
00 Unused
01 Fire
02 Gas
03 HU
04 Silent HU
05 Tamper
06 Intruder
07 Final Exit (FX)
08 Entry Route (ER)
09 ER /Area FX
10 FX /Area ER
11 PTS
12 Switcher
13 Day Alarm
15 Ward Control
16 Fault
17 Closure Supervision
18 Shunt Input
19 Unset
20 Keyswitch Latched
21 Entry Shock
23 Keyswitch Pulsed
B: OUTPUTS
0000 Not Used
0001 Fire
0002 Hold Up ANY
(ie Zones AND Keypads)
0003 Intruder ANY
0004 Final Set ALL (Not G2
endstation)
0005 Misoperation ANY
0006 Confirmed ANY
0007 Tamper
0008 Duress (ie Keypads only)
0009 PA ANY (ie Zones only)
0010 Gas
0014 Siren ANY
0016 Strobe ANY
0017 Omit Rearm ANY
0018 Trouble
0022 Final Set Any
0036 Shunt Fault
0037 Viper Reset
0038 Viper Set/Unset
0039 PIR Latch 1
0040 PIR Latch 2
0060 Digi Reset
0204 Final Set A
10XX Follow Input XX
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 52 Software
INDEX
A
ddressing 9, 21
Alarm responses 39
Area Setting 30
Area Sounders 33, 42
B
attery Test 45, 46
BS.7671 9
C
able Routes 8, 13
Checking System 27
Clean Start 22
Codes
37, 49
Defaults
37, 51
Common Lobby
44
Communications Outputs
17, 18, 19
Compliance Statement 2
Confirmation 17, 18, 19, 35
D
D243:2004 2, 36, 39
Detection
EOL 11
Detection
iD
12, 13
Mode 26
Diagnostics 47
Digi Modem 17
Displays
20, 34
Options 20
Programming 34
Duress Code 37
Duress Output 40
E
MC 8, 9
Directive 2
EN.50131 2
End Station 5, 6
Outputs 14, 15, 16
Engineer
-
Code 37
Force Set 46
Menu 25
Reset/Restore 44
Entry Shock Zone 29, 30
EOL 11
Exit Modes 36
Fault Codes 49
G
uard Code 37
H
old Up 40
i
D
Wiring
12, 13
Indications 20
Options 34
Installation 7, 8
Intelligent Set 43
Keypads
: Addressing 21, 33
Display 20, 34, 46
Output 15
Program 33
Wiring 10, 15
L
evel Setting 30, 44
Line fault Monitor 35, 17-19
Logs 49
Low Voltage Directive 2
M
ains Electricity 9
Manager Code 37
Mode
:
Detection 26
Exit 36
MSX Card 1
O
utput Module 41
Outputs
:
Communications 23,24
Defaults 40
Programming 40
Specifications 16
Tests 46
Wiring 14, 15
P
art Set 30
PD6662 2
Personal Attack 40
Powering Up 21
Power Supply 2, 3
Diagnostics 47
Programming
22, 23, 24
Alarm Responses 39
Codes 37
Detection Mode 26