13. SYSTEM LOGS
Logs are fully date and time
stamped, and are accessible
from either Engineer or
Manager menus.
PANEL LOG includes all set,
unset, alarm events and
system faults etc. The code
holder performing the
operation logged may be
identified by pressing the C
key.
ENGINEER LOG includes all
system faults, together with
details of engineer access, etc.
ACCESS LOG includes all ACCESS
CONTROL events.
Within each log, the D key will
move to the next event,
starting with the most recent
event. The B key will move
similarly, but in the reverse
direction.
To view additional detail, press
the C key. If none is available,
the display will move directly
to the next entry. Press the A
key to return to the main
screen for that entry.
Number of log events available:
Log: Panel Access
G2 panel
625 125
G3+ Panel
1500 500
MSX-44
1500 500
MSX-134
1500 500
MSX-245
1750 750
Identification of Codes:
The user, etc. codes used are
identified by number, as
follows:
Code Identity
Engineer Code Engineer Code
Master
Manager Code
Master Manager Code
User (or
Manager)
01
XX
Codes 01 to XX
programmed in
Manager menu
Duress (or
Guard)
01
XX
Codes 01 to XX
programmed in
Engineer menu
Keyswitch (ie
zone input)
Log identifies as
"Zone Switched"
Fault Codes
Fault codes shown in the
system logs include a numeric
identification of the individual
device at which the fault is
present, eg
'No Comms 203' etc.
The first digit identifies the
device type:
1 = End Station
2 = Keypad
3 = Tag Reader
4 = Zone Expansion Module
5 = Output Module
The remaining digit(s) identify
the individual device of the
type, eg ‘No Comms 203’
identifies the Keypad
addressed as 03, etc.
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 50 Software
14. System Expansion
Expansion of the system is by means of MSX Cards that slot into the
End Station to provide enhanced specifications.
All MSX expansion cards fulfil the requirements of PD6662:2004.
The cards are compatible with the following panels as follows:
Endstation:
G2 iD G2 EoL G3 Plus
24 inputs 16 inputs 74 inputs
Expand to 44 Inputs MSX-44-iD card MSX-44-EoL card N/A
Expand to 134 inputs MSX-134-iD card MSX-134-EoL card MSX-G3plus-134 card
Expand to 256 Inputs MSX-256-iD card MSX-256-EoL card MSX-G3plus-256 card
MSX-iD cards will also fit
into Euro-MERiDIAN 28
panels fitted with endstation
software 4.X.
MSX-EoL cards will also fit
into Euro-MERiDIAN 22
panels fitted with endstation
software 4.X.
MSX-G3plus cards will also
fit into Euro-MERiDIAN 44
panels fitted with endstation
software 4.X.
INSERTING THE MSX CARD
The MSX card must be slotted into the correct socket labelled P1 on the
End Station, as shown.
Slot for MSX card
TEST
PASS